Timber and Civil Defence approval in the UAE: what consultants and contractors need to know

One question comes up on almost every timber enquiry we receive: "Is this material Civil Defence approved?" It usually arrives early, before quantities or drawings, because nobody wants to specify a soffit or a glulam roof and then find it cannot be signed off.
The honest answer is that it depends on the project. Below is how approval works in practice for timber, who is responsible for what, and the documents you should expect from your supplier.
Is there a list of Civil Defence approved timber?
Not in the way most people expect. Civil Defence in Dubai, Sharjah and the other emirates does not hold a standing list of "approved" timber products for soffits, cladding or glulam that you can simply pick from.
Approval for timber is given case by case. The authority looks at the material, where it is used, how it is fixed, and what sits behind it, all within the context of a specific building. A timber soffit under a two-storey office eave and the same boards on a high-rise facade are very different conversations.
So when a supplier tells you their timber is "Civil Defence approved", ask which project that approval was for. It will not automatically carry over to yours.
Who applies for approval?
The consultant or the contractor applies for approval on the project, not the timber supplier.
The UAE Fire and Life Safety Code (2018 edition) sets out how facades and exterior wall coverings are assessed. In practice the main consultant takes responsibility for the facade no objection certificate, supported by a Civil Defence licensed contractor and, where required, an approved house of expertise.
The supplier's job is to give the consultant a complete, credible set of documents so that the submission can be made without gaps.
What documents should a timber supplier provide?
For most timber packages, this is the set we put together for a submission:
- Technical datasheet for the exact product, profile and treatment proposed
- Fire test reports from an accredited laboratory, for example a reaction to fire classification to EN 13501-1
- Declaration of performance and CE marking where the product is covered by a harmonised standard, such as EN 14080 for glulam
- Fire retardant treatment or coating data, if one is used, including the test report for the treated product rather than the untreated timber
- Certificates of origin and chain of custody (FSC or PEFC) where the specification asks for them
- Installation details showing fixings, substructure and cavity arrangements, which the consultant will coordinate with the facade design
Untreated timber on its own usually achieves a modest reaction to fire class. Where a project needs a higher class, the usual routes are a fire retardant impregnation or a tested coating system. Whichever route is chosen, the test report has to match the product actually being supplied. A report for a different species, thickness or treatment will not help the submission.
Soffits, cladding and glulam: how the questions differ
Timber soffits
Soffits sit overhead and often run continuously along a facade, so consultants look closely at what is above them, how the cavity is closed off and how far the timber runs. Modified timbers such as Accoya and Thermory are popular here because they stay stable and hold a coating well. See our comparison: Accoya or Thermory for soffits and cladding.
Timber cladding
For cladding the conversation is about the whole wall build-up, not just the boards. The consultant will want to see that the timber, substructure, insulation and cavity barriers have been considered together.
Glulam structure
For exposed glulam beams and columns, the questions are usually about fire resistance of the member (how long it carries load in a fire), which is calculated from its charring rate and size, as well as the surface classification. Your structural engineer and the glulam manufacturer's documents work together here.
How to avoid delays
A few things make a real difference to how smoothly approval goes:
- Bring the supplier in early. If we know the location and required fire performance at design stage, we can propose a product that already has the right test evidence.
- Agree the target class first. Ask the consultant what classification they need before comparing prices. A cheaper board without the right report can cost more in time than it saves.
- Keep product and paperwork matched. Any change of species, thickness or coating means checking that the reports still apply.
- Allow for lead time. Timber for UAE projects is usually imported to order. Our typical lead time is five to six weeks, or 8 to 12 weeks for Accoya, so documentation and approval should run alongside procurement, not after it.
Frequently asked questions
Is any timber product pre-approved by Civil Defence in the UAE?
Not as a general rule. Approval for timber soffits, cladding and glulam is given project by project, based on the material, its location and the full build-up.
Who submits the timber to Civil Defence?
The project consultant or contractor makes the submission. The timber supplier provides the technical datasheets, fire test reports and certifications that support it.
Can untreated timber be used on a facade in Dubai?
It depends on the building, the location of the timber and the classification required. Many projects use fire retardant treated or coated timber to reach the required class. The consultant confirms what is acceptable for that building.
Does a fire test report from overseas count?
Reports from accredited laboratories to recognised standards such as EN 13501-1 are commonly used in submissions. The consultant and the authority decide whether the evidence is sufficient for the project.
How early should we involve the timber supplier?
At design stage if possible. It is much easier to choose a product that already has the right test evidence than to find evidence for a product after it has been specified.
Talk to us about your project